Products | Radio Frequency (RF) Equipment |

English 中文

  • Bidirectional, RF AGC, 1.2GHz, Plug in : WF-1232KL-II

Bidirectional, RF AGC, 1.2GHz, Plug in : WF-1232KL-II

WF-1232KL-II


WF-1232KL-II building amplifier is suitable for HFC bidirectional network, which mainly used to amplify CATV image and digital signals. It is a remote terminal in the CATV transmission system with reasonable circuit, scientific structure and excellent performance index.

Product overview

* 1.2GHz, support DOCSIS 3.1 system.

* Downstream supports RF AGC control.

* Equalizer continuously adjustable.

* External RF test point.

* 5 ~ 1218MHz, Frequency division optional.

* Downstream Gain≥ 32 dB.

* EQ adjustment range: 0 ~ 18dB.

* Upstream Gain≥ 17 dB.

* Power Consumption≤ 5W.

* Operating Temperature: -20℃ ~ +55℃.

* Operating Voltage: AC 90 ~ 240V (50Hz) .

* Dimension: 200mm(L)X 115mm(W)X 55mm(H).

Parameter

Item

Unit

Parameter

Downstream

Frequency range

MHz

110 -1218

Minimum gain

dB

32

Flatness in Band

dB

±1

Return loss

dB

16

@110MHz, -1.5 dB/octave, Min>11

Noise figure

dB

7

Input ATT

dB

0-15

Input EQ

dB

0-10

Interstage ATT

dB

0-15

Interstage EQ

dB

4/8

CNR

dB

≥52

European standard 41CH analog signal, input: 75dBuV,

Output: 107dBuV@1218MHz,

Interstage EQ: 8dB

CTB

dB

≥60

CSO

dB

≥60

MER

dB

≥40

110-862 MHz in full configuration, QAM256 digital signal

Input: 75dBuV, Output: 104dBuV@1218MHz

Interstage ATT: 3Db, interstage EQ: 8dB

BER

 

1.00E-09

Upstream

Frequency range

MHz

30-85

Gain

dB

≥23

Flatness in Band

dB

±1

Return loss

dB

15

Noise figure

dB

6

Input ATT

dB

0-20

Interstage ATT

dB

0-20

Interstage EQ

dB

0/4

MER

dB

≥38

European standard 41CH analog signal, EQ: 8 dB

Output level 110 dBuV@1218MHz

BER

 

1.00E-09

NPR dynamic range

dB

30

@36 dB CNIR  

Others

Waterproof level

 

IP41

Supply voltage

V

90-240

Test port

dB

-30±2

F connector

 

Inch, female

EMC

 

EN50083-2-2006  table10-classA

Impedance

Ω

75

Power consumption

W

18

Surge

KV

4 (RF port)

ESD

KV

2 (RF port)

Operating temperature

-20+50

Dimension

mm

200(L)×115(W)×55(H)


Size chart
Download